Paracelsus Medizinische Privatuniversität (PMU)

Forschung & Innovation
Publikationen

MRI Visibility and MR-DSA Concordance of the Nuvascular Harbor Intrasaccular Occlusion Device

#2026
#Brain Sciences

PMU Autor*innen
Gokce Hatipoglu Majernik, Andreas Ollerer, Teresa Lassacher, Emre Kaya, Dzmitry Kuzmin, Andrea Janu, Christoph Griessenauer, Monika Killer-Oberpfalzer

Alle Autor*innen
Gokce Hatipoglu Majernik, Andreas Ollerer, Teresa Lassacher, Emre Kaya, Dzmitry Kuzmin, Andrea Janu, Christoph Griessenauer, Monika Killer-Oberpfalzer

Fachzeitschrift
Brain Sciences

Kurzfassung

Highlights What are the main findings? MR-based occlusion assessment demonstrated high concordance with DSA. The Harbor intrasaccular device provided consistent and reliable visualization on MR imaging. What are the implications of the main findings? MRI may serve as a reliable non-invasive alternative for aneurysm follow-up. MR-based follow-up strategies could reduce the need for invasive angiography.Highlights What are the main findings? MR-based occlusion assessment demonstrated high concordance with DSA. The Harbor intrasaccular device provided consistent and reliable visualization on MR imaging. What are the implications of the main findings? MRI may serve as a reliable non-invasive alternative for aneurysm follow-up. MR-based follow-up strategies could reduce the need for invasive angiography.Abstract Background/Objectives: This GLP (Good laboratory practice) study evaluates the MRI compatibility and occlusion performance of the Nuvascular Harbor intrasaccular device for the treatment of bifurcation and sidewall aneurysms in a rabbit aneurysm model. Methods: A total of 27 New Zealand White rabbits with 33 surgically created aneurysms (22 bifurcation, 11 side wall) were included and allocated to 90-day (n = 12) or 180-day (n = 15) follow-up. After exclusion of one aneurysm due to parent vessel occlusion and one aneurysm unsuitable for treatment, 31 treated aneurysms remained for analysis. All animals underwent DSA and 3T MRI, including TOF-MRA, FLAIR, DWI, and SWI sequences. Occlusion status was independently graded using the Raymond-Roy Occlusion Classification (RROC), and intermodality agreement was assessed. Results: MR-based occlusion assessment demonstrated strong agreement with DSA, with exact Raymond-Roy class concordance in 80.6% of cases and clinically relevant agreement (adequate vs. incomplete occlusion) in 96.8%. Agreement analysis showed substantial concordance (Cohen's kappa = 0.65) and a strong positive correlation (r = 0.79). Adequate occlusion rates were comparable between modalities (87.1% on MRA vs. 83.9% on DSA), supporting the reliability of MR imaging for non-invasive occlusion assessment, reflecting consistent device visibility on MR imaging. Conclusions: The Harbor device provides a promising solution for follow up aneurysm occlusion with increased MR visibility, enabling safer, contrast- and radiation-free follow-up. This study emphasizes the need for future endovascular devices to integrate imaging compatibility into their design to enhance long-term patient follow up.

Keywords

ANEURYSMS, MR visibility, Intrasaccular device

Weitere Publikationen

#2026
#Originalarbeit

Christoph J Griessenauer, Sherief Ghozy, Hamza A Salim, Nimer Adeeb, Basel Musmar, Alessandra Biondi, Fritz Wodarg, Thomas Liebig, Tufail Patankar, Sal Lamin, Mario Martínez-Galdámez, Christophe Cognard, Jens Fiehler, Franziska Dorn, Mohammad B Abuzahra, Nicole M Cancelliere, Jose Danilo Bengzon Diestro, Oktay Algin, Sovann V Lay, Adrien Guenego, Leonardo Renieri, Joseph Carnevale, Guillaume Saliou, Panagiotis Mastorakos, Kareem El Naamani, Eimad Shotar, Markus Möhlenbruch, Michael Kral, Charlotte Chung, Mohamed M Salem, Ivan Lylyk, Paul M Foreman, Hamza Shaikh, Vedran Župančić, Muhammad U Hafeez, Joshua Catapano, Muhammad Waqas, Ozgür Ozates, Gıyas Ayberk, James D Rabinov, Yifan Ren, Clemens M Schirmer, Mariangela Piano, Anna L Kühn, Caterina Michelozzi, Robert M Starke, Ameer E Hassan, Mark Ogilvie, Anh Nguyen, Peter B Sporns, Jesse Jones, Waleed Brinjikji, Marie T Nawka, Marios Psychogios, Christian Ulfert, Bryan Pukenas, Jan-Karl Burkhardt, Thien Huynh, Juan Carlos Martinez-Gutierrez, Muhammed Amir Essibayi, Sunil A Sheth, Diana Slawski, Rabih G Tawk, Benjamin Pulli, Boris Lubicz, Pietro Panni, Ajit S Puri, Guglielmo Pero, Eytan Raz, Hamed Asadi, Adnan Siddiqui, Elad I Levy, Neil Haranhalli, David Altschul, Andrew F Ducruet, Felipe C Albuquerque, Robert W Regenhardt, Christopher J Stapleton, Peter Kan, Vladimir Kalousek, Pedro Lylyk, Srikanth R Boddu, Jared Knopman, Stavropoula I Tjoumakaris, Hugo H Cuellar-Saenz, Pascal M Jabbour, Frédéric Clarençon, Nicola Limbucci, Vitor Mendes Pereira, Aman B Patel, Monika Killer-Oberpfalzer, Adam A Dmytriw, Constantin Hecker The Contour Neurovascular System Versus Woven Endobridge for Endovascular Embolization of Cerebral Aneurysms